8-24W · 95/145mm cutouts · 3000/4000/6000K — DIP selectable TRIAC downlight for hotels and shops.
Home / Product / Led Downlight / PURE-DS
PURE-DS DIP selectable TRIAC downlight in white — preset the wattage and white on site, dim it on the wall dimmer.
PURE-DS LED Downlight
PURE-DS · 8-24W · 110lm/W · 3000/4000/6000K · UGR<22
The PURE-DS is a CCT selectable TRIAC downlight built in China for hotels and shops, covering 8W to 24W across 95mm and 145mm cutouts — set power and white with the DIP switch at install (8/10/12W in the small housing, 18/20/24W in the large one), then dim the preset output on the existing TRIAC wall dimmer. Made in China by Low Carbon Teclux, one fitting replaces nine stock combinations per housing.
This low glare DIP selectable downlight holds Ra90 with UGR under 22 for corridors, guestrooms, lobbies and retail floors. It is the preset-and-dim answer to the fixed-CCT PURE-S DL02 recessed downlight family, while the PURE-DW dim to warm downlight serves rooms that must end the evening in candlelight.
- 8-24W DIP preset: 8/10/12W small, 18/20/24W large
- 3000/4000/6000K DIP preset, 110lm/W Ra90 COB
- UGR<22, COB 24/36/55° beams, TRIAC wall-dim
- 95/145mm cutouts, 9 trim colors, DL02 housings
Explore PURE-DS DIP Selectable Downlight Family
Preset stock, dimmed light — two housings for every room
The PURE-DS DIP selectable TRIAC downlight pairs DL02 housings with a two-bank preset switch, factory-direct from China. This low glare DIP selectable downlight stocks two fittings to serve corridors, guestrooms, lobbies and shops from 8W to 24W.
One SKU, Nine Combinations
3 powers × 3 whites per housing — stock two fittings
Each PURE-DS fitting carries a two-bank DIP switch inside a die-cast aluminum DL02 housing with an open heat-sink path — one bank sets 8/10/12W in the small housing or 18/20/24W in the large one, the other sets 3000/4000/6000K. Nine combinations per housing.
- One fitting per housing replaces nine fixed SKUs
- Contractors dial the site spec at install with the power off
- Die-cast aluminum cup plus vented trim ring
- 220~240VAC 50/60Hz, IP20 for indoor ceilings
Ra90 True Color, UGR22 Low Glare
110lm/W Ra90 COB in 24/36/55° — stated per CCT
Output is rated at 110lm/W on 4000K: 880-1320lm small, 1980-2640lm large. The 3000K warm step runs about 5-8% lower by phosphor physics and the 6000K step about 3% higher — the datasheet states all three, so quotations never oversell. The COB lens delivers Ra90 accent-grade color deep behind the trim.
- COB at Ra90, 24/36/55° for corridors, lobbies and shops
- UGR<22 across every optic, no bare source in view
- Wattage ±5% plus CCT-stated lumens for honest spacing
Retrofit Ready, Dimmer Optional
No new control wire — fixed now, TRIAC later
Running hotels and shops cannot close for rewiring. PURE-DS keeps the installed phase-cut wall dimmers and drops 1:1 into the existing 95mm and 145mm cutouts — DIP presets the ceiling output with the power off, the wall dimmer takes it from there. No signal cable, no apps, no commissioning.
- 1:1 swap in existing 95/145mm cutouts — old fixed downlight out, preset-and-dim in
- Runs on installed TRIAC / phase-cut wall dimmers (confirm dimmer model at order)
- Retrofit rooms and new zones share housings, trims and curves — one visual language
- Lamp-plus-driver changeover only — ceiling, wiring and business hours untouched
Why PURE-DS for Hotels and Shops
Preset stock, dimmed light from the same DL02 housings
Stock Two Fittings, Serve Every Room
Guestrooms and corridors take the small 95mm housing at 8-12W — lobbies and retail floors take the large 145mm housing at 18-24W, each preset to 3000, 4000 or 6000K on site. All share the same DL02 housings and nine trims, so extended floors read as one family. Start from the LED downlight family index to compare the full range.
The fixed-CCT PURE-S DL02 recessed downlight family stays the choice for projects that never change spec; where ceilings take splashes, use the MIST-P DL03 front-IP44 family instead. Against tunable white (DT8 drivers, wireless mesh), PURE-DS wins on three things:
- Lower stock cost — one preset fitting per housing, no addressing hardware, no wireless nodes, no commissioning time
- No rewiring — runs on the existing 2-wire mains plus TRIAC wall dimmers, while DT8 needs two extra signal wires; retrofit and new builds share the same wiring
- Upgrade means adding one dimmer — if the live wire has no dimmer yet, just add one TRIAC dimmer on it; brightness follows the preset level, no apps or scenes to program
| Order option | Output | CRI | Best for |
|---|---|---|---|
| DIP small housing | 880-1320lm, 8/10/12W preset | Ra90 | Corridors and guestrooms |
| DIP large housing | 1980-2640lm, 18/20/24W preset | Ra90 | Lobbies and retail floors |
| TRIAC dimming | Phase-cut wall dimmer | Ra90 | Retrofit and new zones |
Good to know before you order: DIP presets power and CCT with the power off — the fitting then works two ways. Wire it direct to mains and it runs as a regular fixed downlight at the preset level; add one TRIAC wall dimmer on the live wire when dimming is needed, with no signal wires, no apps and no recommissioning.
Datasheet
Select a size to view full specifications
| LC-DL02-DIP-12W | |
|---|---|
| Model | LC-DL02-DIP-12W |
| Wattage | DIP 8/10/12W ±5% |
| Lumen Output | 880/1100/1320lm at 110lm/W, 4000K rated (3000K approx. -5~8%, 6000K approx. +3%) |
| Size (Ø x H) | Ø105xH42mm |
| Cutout | Ø95mm |
| Light Source | COB, DIP power + CCT, bevel / curved trim |
| CCT | 3000/4000/6000K (DIP preset, power off) |
| CRI | Ra90 |
| Beam / Glare | COB 24/36/55°, UGR<22 |
| Dimming | TRIAC phase-cut wall dimmer |
| Voltage / Trim | 220~240VAC 50/60Hz; 9 colors |
| LC-DL02-DIP-24W | |
|---|---|
| Model | LC-DL02-DIP-24W |
| Wattage | DIP 18/20/24W ±5% |
| Lumen Output | 1980/2200/2640lm at 110lm/W, 4000K rated (3000K approx. -5~8%, 6000K approx. +3%) |
| Size (Ø x H) | Ø160xH48mm |
| Cutout | Ø145mm |
| Light Source | COB, DIP power + CCT, bevel / curved trim |
| CCT | 3000/4000/6000K (DIP preset, power off) |
| CRI | Ra90 |
| Beam / Glare | COB 24/36/55°, UGR<22 |
| Dimming | TRIAC phase-cut wall dimmer |
| Voltage / Trim | 220~240VAC 50/60Hz; 9 colors |
Variants in series
Two trims, two housings — pick the face by ceiling
Curved-trim COB — LC-DL02-DIP-xxW-C
Optic type
COB lens, curved trim
CRI / Beam
Ra90, 24/36/55°
Cutout
95 / 145mm by size
Best for
Corridors and guestrooms, DIP preset
Bevel-trim COB — LC-DL02-DIP-xxW-B
Optic type
COB lens, bevel trim
CRI / Beam
Ra90, 24/36/55°
Cutout
95 / 145mm by size
Best for
Lobbies and retail displays
Lighting Calculator
Estimate how many PURE-DS heads your space needs — simplified estimate without IES
FAQ
Quick answers about the DIP series
Set two switch banks with the power off — 8/10/12W in the 95mm housing or 18/20/24W in the 145mm housing, plus 3000/4000/6000K. One fitting covers nine combinations with no fixed-SKU wall to stock, across the LED downlight family index.
Yes, the preset sets the ceiling and the wall dimmer sets the mood — the DIP switch fixes the maximum output and the existing phase-cut wall dimmer dims that level with no new control wiring. Confirm your dimmer model in the inquiry so the factory matches the smoothest driver batch.
Warm phosphor converts less efficiently — 3000K runs about 5-8% below the 4000K rated lumens, while 6000K runs about 3% above. Quote and space each room by the CCT you actually order; for the full low-end checklist, see the dim to warm lighting guide for restaurants and hotels.
Yes, all nine trims run both housings — matte white, black, silver, matte black, gun black, champagne gold, rose gold and bright silver. Confirm your ceiling finish in the inquiry so the factory kits one color across the 95mm and 145mm cutouts.
Standard warranty is 5 years with spare drivers per shipment, sized from 8W corridors to 24W lobbies in one selectable family.