LOW CARBON TECLUX
LED Industrial Light Manufacturer
We build LED industrial lights for poultry houses, warehouses and corridors: sealed tri-proof battens that survive ammonia and washdowns, UFO and DALI linear high bays at 170lm/W, and microwave-sensor bulkheads with emergency options. Everything ships factory-direct since 2010. Start from the full product catalog, compare LED downlights for clean interiors, or size a warehouse in our lighting calculator.
Made in Zhongshan, China · No MOQ · Samples: 7 working days · Bulk orders: 15-25 working days · FOB Shenzhen
Led industrial light
Sealed battens and tubes for farms, warehouses, car parks and wet rooms
Sealed tubular lights
Four sealed tubes — all-plastic against ammonia, a true round tube and a thin linkable PMMA run for farms and industry. Lengths run 600/1200/1500mm (2/4/5ft).
DURA-P Ammonia-Proof
All-plastic ammonia-resistant tube for chicken houses
View DURA-P Tri-Proof Tube
TUBU-C Linkable
Thin linkable tube for poultry and farm runs, PMMA option, 5-year warranty
Get TUBU-C QuoteSealed batten lights
Eight sealed battens — pick by width, profile and mounting. Same 2/4/5ft lengths; suspended and rail-mounted versions for high ceilings and factories.
WIDE-A Wide Flood
Widest diffuser in the family for low warehouses, 600/1200/1500mm
Get WIDE-A Quote
High-bay for racking aisles
Above ~6 m only a lensed high bay holds floor lux — diffuse battens wash walls up there.
Corridor bulkheads
Stairs, entries and bathrooms — compact sensor bulkheads with emergency backup.
AQUA-R Sensor Rect.
Rectangular sensor bulkhead for corridors, emergency
View AQUA-R Rectangular BulkheadOptions and selection
Four functions, multiple housings — mix and match per site
Dimming
- 0-10V: trims 10-100% for aisles and car parks on simple controllers.
- DALI-2: addresses each fitting from the bus — same logic as the FORT-A high bay.
Sensor
- Microwave: sees around corners, step-dims empty lanes.
- Set sensitivity and hold-time per site — see the sensor guide.
Emergency
- 3-hour backup: reduced output on mains failure.
- Covers stairs, exits and parking routes.
Linkable run
- Through-wiring: up to 10 TUBU-C fittings on one feed.
- One entry point for long corridors, no extra cable runs.
Quick comparison — why each housing fits its place
Rule of thumb: PC battens and tubes spread a wide ~110° flood with no lens control, so they suit low ceilings (2–5 m) — parking decks, corridors, poultry and food rooms. Above ~6 m only the lensed FORT-A high bay (50°×100° optic) still puts lux on the floor instead of the walls.
| Image | Model | Housing and optics | Protection | Ceiling | Best for — why |
|---|---|---|---|---|---|
![]() | TUBU-A | round tube Ø76mm | IP65 | 2.5–5 m | Damp rooms and wash areas — 150lm/W Ø76mm round tube; sheds water and dust where flat battens trap grime on top, twist-off end cap for fast corridor rows. |
![]() | TUBU-C | thin linkable tube, PMMA option | IP65 | 3–5 m | Poultry and farm runs — links into long rows off one feed; PMMA resists ammonia haze better than standard PC. |
![]() | DURA-P | sealed all-plastic tube, diffuse | IP65 | 3–5 m | Chicken houses (details) — plastic body stands ammonia air that corrodes alloy end-caps; sealed ends survive daily pressure washing. |
![]() | WIDE-A | wide PC batten, ~110° flood | IP65 | 3–5 m | Warehouses and damp workshops — widest diffuser in the family covers low ceilings evenly; sealed shell where painted metal rusts. |
![]() | SLIM-B | narrow batten 48mm | IP65 | 2.5–4 m | Corridors and service runs — 48mm is the narrowest body in the family, made for tight mounting spots. |
![]() | VAPO-A | narrow batten 62mm | IP65 | 3–5 m | Workshops and utility rooms — the default vapor-tight pick where no special profile or mounting applies. |
![]() | OVAL-A | oval batten 75×68mm | IP65 | 2–3.5 m | Wet rooms and wash areas — rounded oval diffuser instead of a flat rectangle. |
![]() | ALUM-A | batten on exposed alu rail + brackets | IP65 | 3–6 m | Factories and plant rooms — exposed heatsink rail on bracket feet, the only rail-mounted build here. |
![]() | TOLS-W | flat batten 79mm wide | IP65 | 3–5 m | Workshops and plants — 79mm is the widest measured flat profile, so one fitting covers more floor per watt. |
![]() | TOLS-N | flat batten 74×27mm, twist-off end cap | IP65 | 2.5–4 m | Car parks and corridors — twist-off end cap opens without tools for faster wiring and maintenance. |
![]() | SUSP-A | wide PC batten, wire suspension | IP65 | 3–6 m | High open ceilings — wire kit drops the batten into the work zone where surface mounting is too far. |
![]() | FORT-A | aluminum + tempered-glass 50°×100° lens | IP65 | 6–12 m | High racking aisles, manufacturing — the only fitting here with real beam control; the lens throws lumens down the aisle so floor lux holds at height where 110° PC battens wash walls and fall off. |
![]() | AQUA-D | compact round bulkhead, wide flood | IP65 | 2–3.5 m | Corridors, stairs and entries — round body with wide sensor coverage; microwave sensor + emergency as standard (round details). |
![]() | AQUA-AB | round PC amber bulkhead, blue-free glow | IP65 | 2–3.5 m | Beach-facing walls, boardwalks and resort corridors — amber engine with the same sensor + emergency platform (amber details). |
![]() | AQUA-R | compact rectangular bulkhead, wide flood | IP65 | 2–3.5 m | Corridors, stairs and bathrooms — rectangular body sits cleaner over doors and in compact rooms; microwave sensor + emergency as standard (rectangular details). |
Sizes run 600/1200/1500mm with 3000/4000/5000K; mounting is surface or suspended, tubes add clamp fit. Pick PMMA over PC where acids, oils or car-wash detergents attack the cover, and 316 clips where rust streaks matter. T8 retrofit shells reuse the same extrusion without light source or driver. For lux and spacing math use the lighting calculator before fixing counts.
What our LED industrial lights cover
Factory notes for distributors and project buyers
Tri-proof means sealed against water, dust and chemistry: one fitting family for places that kill ordinary indoor lights. As an LED tri-proof light manufacturer, we build this range for poultry houses, warehouses, car parks, corridors and wet rooms: sealed tubes that survive ammonia air and washdowns, linear high bays with dimming for racking aisles, and sensor bulkheads with emergency backup for stairs and entries.
Save energy with sensors, not just efficacy. The range works with microwave sensors that see around corners, presence sensors that track occupied versus unoccupied states, infrared (PIR) versions for body-heat detection in defined areas such as bathrooms, and daylight harvest sensors that trim output when sunlight suffices — dimming or switching off empty aisles and corridors instead of burning full power all night. DALI-2 models such as the FORT-A linear high bay take this further to Class A Ready under EN ISO 52120-1, the highest EU building-automation grade: DALI Parts 251, 252 and 253 report energy and diagnostics over the bus, corridorDIM automates corridor levels, and constant-light-output control holds brightness steady as LEDs age. Check IP and IK ratings, sensor type and hold-time settings, and whether the driver dims with your building system before comparing lumens. Clean retail interiors without moisture or dust belong with LED downlights and track lights instead.
Typical applications: broiler and layer houses, distribution centers and workshops, office corridors, stairwells and bathrooms, car parks and entries. Sensor behavior is explained in the PIR vs microwave vs presence sensor guide.
FAQ
Quick answers before you specify
Ammonia, dust and pressure washers kill ordinary alloy tubes within seasons. The DURA-P poultry tube uses an all-plastic sealed body in 40W and 60W that stands ammonia air and daily washdowns.
Under ~5 m, a PC batten (WIDE-A/VAPO-A/TOLS-N) is enough — its ~110° flood spreads evenly at low height. Above ~6 m with racking, take the FORT-A DALI linear high bay: its 50°×100° lens throws light down the aisle where a diffuse batten would wash the walls and lose floor lux. Run the lighting calculator first to fix fixture counts from your lux target.
Microwave presence detection reaches around corners and through thin partitions, which is why corridors use it, and also why sensitivity and hold-time must be set per site. The sensor guide covers ghost triggers and placement.
Round AQUA-D bulkheads suit corridors and stairwells with wide sensor coverage. Rectangular AQUA-R bulkheads sit cleaner over doors and in compact bathrooms.
Three hours at reduced output on mains failure — enough for stairs, exits and parking routes. Order the emergency option per fitting, not per run.
Up to 10 TUBU-C fittings on one electrical feed with through-wiring — one entry point covers a long corridor without extra cable runs.
Send Message